9695-02/ 9695-03 – Clamp On Sensor

Hioki

For measuring load current, voltage output sensor

Hioki

9695-02 – Clamp On Sensor, 50 A AC. For the PW3360/65, 3169, PW3198 and similar products

9695-03 – Clamp On Sensor, 100A AC. For the PW3360/65, 3169, PW3198 and similar products

Overview

Hioki current sensors are best-in-class devices for use with power meters, and PQAs.
The 9695-02 is a 50 A AC clamp sensor with voltage output for measuring load current.
The 9695-03 is a 100 A AC clamp sensor with voltage output for measuring load current.

Key Features

  • High ±0.3% accuracy
  • For inverter devices or commercial power lines
  • For power meters and power loggers (may require the 9219)
  • Fits in narrow spaces due to compact design
  • CAT III 300V
9695-02 9695-03
Rated measurement current 50 A AC 100 A AC
Max. measurement current Continuous 60 A (45 to 66 Hz) Continuous 130 A (45 to 66 Hz)
Output rate 10 mV AC/ A 1 mV AC/ A
Amplitude accuracy (45-66 Hz) ±0.3 % rdg. ±0.02 % f.s. (*1)
Phase accuracy ±2° (45 Hz to 5 kHz) ±1° (45 Hz to 5 kHz)
Amplitude frequency characteristics Within ±1% at 40 Hz – 5 kHz (deviation from amplitude accuracy)
Max. rated voltage to earth 300 V AC rms or less (Insulated conductor)
Measurable conductor diameter φ 15 mm (0.59 in) or less
Operating temperature and humidity 0°C to 50°C (32°F to 122°F), 80% RH or less (no condensation)
Dimensions and mass 50.5 mm (1.99 in)W × 58 mm (2.28 in)H × 18.7 mm (0.74 in)D, 50 g (1.8 oz)
Output terminal : M3 terminal (outside 3 mm, 0.12 inch diameter)
Option: Connection cable 9219 (3 m, 9.84 ft length)