Basic specifications (Accuracy guaranteed for 1 year) |
DC voltage |
60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ?0.025 % rdg. ?2 dgt. |
AC Voltage* |
60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz – 100 kHz, Basic accuracy 45 – 65 Hz : ?0.2 % rdg. ?25 dgt. (True RMS, crest factor 3) |
DC + AC Voltage* |
6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz – 100 kHz, Basic accuracy 45 – 65 Hz : ?0.3 % rdg. ?30 dgt. (True RMS, crest factor 3) |
Resistance |
60.000 ? to 600.0 M?, 8 ranges, (Conductance: 600.00 nS, DT4282 only), Basic accuracy: ?0.03 % rdg. ?2 dgt. |
DC current |
600.00 _A to 10.000 A, 6 ranges, Basic accuracy: ?0.05 % rdg. ?5 dgt. |
AC Current* |
600.00 _A to 10.000 A, 6 ranges, Basic accuracy 45 – 65 Hz : ?0.6 % rdg. ?5 dgt. (True RMS, crest factor 3); Frequency characteristics: 20 Hz – 20 kHz (at 600 _A to 600 mA range) |
AC Current* (use with Clamp on probes) |
N/A |
Peak |
DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated); AC V, DC/AC A measurement: Signal width 1 msec or more (single), 250 _sec or more (repeated) |
C (capacitance) |
1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ?1.0 % rdg. ?5 dgt. |
Continuity Check |
Continuity threshold: 20/50/100/500 ?, Response time: 10 ms or more |
Diode test |
Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages |
Frequency |
AC V, DC+AC V, AC A measurement, at pulse width 1 _s or more (50 % duty ratio); 99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ?0.005 % rdg. ?3 dgt. |
dB conversion |
Standard impedance setting (dBm), 4 ? to 1200 ?, 20 stages; Display dB conversion value of AC voltage (dBV) |
Temperature (thermocouples) |
K: -40.0 ?C to 800.0 ?C (-40.0 ?F to 1472.0 ?F); Add accuracy of the Thermocouple probe to main unit accuracy: ?0.5 % rdg. ?3 ?C |
Other functions |
Filter function (Remove harmonic noise, use only at 600 VAC, 1000 VAC ranges), Display value hold, Auto hold, Max/Min value display, Sampling select, Relative display, Measurement memory (400 data), Auto-power save, USB communication (option), 4-20 mA % conversion |
Display |
Main and Sub displays: 5-digits LCD, max. 60000 digits |
Display refresh rates |
5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s ) |
Power supply |
LR6 (AA) alkaline batteries _4, Continuous use: 100 hours |
Dimensions and mass |
93 mm (3.66 in) W _ 197 mm (7.76 in) H_ 53 mm (2.09 in) D, 650 g (22.9 oz) (with test leads holder and batteries) |
Accessories |
Test Lead L9207-10 _1, Instruction Manual _1, LR6 Alkaline Battery _4 |