EDX-100A-2 – Universal Recorder

Kyowa

The EDS-400A is a compact & lightweight recorder for acquiring 4 channels of strain and voltage signals.

Kyowa

EDX-100A-2 – Universal Recorder

Summary

  • Models of 1 slot, 2 slots, and 4 slots are available
  • LAN port for establishing multichannel network up to 256 channels
  • High-speed sampling at 100 kHz (10 kHz for 16-channel)
  • Decentralized arrangement with Synchronous Extension Units ESYN-30A is possible

Technical Specifications

Card Slots 2
Max.Channels 16
Analog Input Optional conditioner cards Implement with DPM, CDV, CTA, CFV, CCA, CVM installed
CAN Data Input Provided by the optional CAN-41A
Voice Memo Input 1 channel. An optional dedicated remote control unit RCU-41A enables recording of voice memo during measurement in manual mode.
Playback of recorded voice memo requires an optional Data Analysis Software DAS-200A.
Sampling Methods Synchronous sampling of all channels
Sampling Frequency Selection 1-2-5 series in a range of 1 Hz to 100 kHz
2n series in a range of 2 Hz to 65536 Hz
Sampling Frequencies (1-2-5 series) 1 Hz to 100 kHz for 1-channel measurement
1 Hz to 50 kHz for 3-channel measurement
1 Hz to 20 kHz for 8-channel measurement
1 Hz to 10 kHz for 16-channel measurement
1 Hz to 5 kHz for 32-channel measurement
1 Hz to 1 kHz for CAN data measurement
Data Storage CF cards recommended by Kyowa
(128 MB to 8 GB; 45x speed or higher)
Up to 2 GB data for 1 time of measurement
Setting Conditions Online : From the PC via LAN or USB port
Offline : By reading from the CF card which has measuring conditions written with the DCS-100A data acquisition software
Saving Conditions Amplifier setting conditions and measuring conditions are saved in the internal nonvolatile memory, enabling immediate setup with previous conditions upon power-on.
Measuring Modes
Manual Data recording is manually started or stopped when data is recorded to a preset number of measured data.
Manual mode allows recording of voice memo during data recording.
Trigger Data recording is automatically started when the preset trigger condition is satisfied.
Note that any CAN data mustn’t be used as trigger condition
Interval Data recording is periodically made at preset intervals.
Manual Start/Stop of Data Recording Possible by using the PC or by pressing the switch on the front panel or from the dedicated remote control unit
Balance Adjustment Strain input channels is balanced by pressing the BAL. switch on the front panel or from the dedicated remote control unit or from the PC.
Saved Data Format Kyowa standard format KS2, which enables data analysis with the optional Data Analysis Software DAS-200A
Collecting Data LAN or USB port enables online data transfer to the PC, while CF card enables offline data transfer.
TEDS Reads sensor’s information and sets to channel condition automatically.
Supported conditioner cards: CDV-40B (-F), DPM-42B (-F), DPM-42B-I (-F), CCA-40A (-F), CDV-44AS, CDA-44AS/45AS, CVM-41A, AD-40AS (-F)
Synchronous Operation Synchronous cable enables cascade connection of up to 8 units of the EDX-100A. While data is recorded as a separate file in the CF card inserted into each unit, files of all cards are combined into a single file after online or offline data transfer to the PC.
Analog Output Except for CDV-40B (-F), AD-40AS (-F), CAN-41A.
conditioner cards provide an analog output connector, enabling voltage monitoring (?5 VFS).
CF Card Slot 1 (For data recording and condition setting)
Interfaces LAN and USB (For control and data transfer), switchable
LAN I/F: 10BASE-T/100BASE-TX, Connector: RJ45 modular jack
USB I/F: Conforms to USB 2.0 (High speed), Connector: Series B receptacle
Operation Switches REC/PAUSE: Starts/pauses data recording.
STOP: Stops data recording.
BAL.: Execute balance adjustment.
READ: Reads and set conditions.
ID: Sets ID No. of EDX-100A.
LAN/USB: Switches communication port.
Indicators Operation status indicator LEDs: 7
Channel status indicator LEDs: The number corresponds to the number of channels provided.
External Control Connectors CONT IN and CONT OUT (For remote control and synchronous operation)
Operating Temperature 0 to 50?C
Operating Humidity 20 to 90% RH (Non-condensing)
Storage Temperature -20 to 60?C
Vibration Resistant ?29.42 m/s2 (3 G), 5 to 55 Hz (When operating)
?49.03 m/s2 (5 G), 5 to 55 Hz (When not operating)
Impact Resistant 196.1 m/s2 (20 G) /11 ms
EMC Directive EN61326-1 (Class A)
Power Supply 10 to 18 VDC
Connector: RM12BRD-4PH (Hirose)
DC power supply or optional dedicated AC adapter is required.
Current Consumption Approx. 1.8 A (When operated on 12 VDC with 2 CDV-40B cards mounted and full load applied)
Dimensions 92.5 W x 132.5 H x 255 D mm (Excluding protrusions)
Weight Approx. 1.8 kg (2.0 kg with 2 CDV-40B cards mounted)
Standard Accessories DC power cable P-76
Ground wire P-72
USB cable N-38
CF card
DVD (Dynamic data acquisition software DCS-100A)
*No DCS-100A for models with suffix “-0”.
Optional Accessories USB cable N-39 (2 m)
Synchronous cable N-95, N-128
Camera synchronous cable N-98, N-99, N-101
AC adapter UIA 345-12 (For U.S.A.: UNI345-1238)
Cable fixture
Synchronous extension unit ESYN-30A
Remote control unit RCU-41A
Battery unit for instantaneous power failure EDB-41B
Monitor unit EMON-20A
Dummy panel EDX-2000-DUMMY

 

Others

N/A