EDX-5000A-80 – Memory Recorder/Analyzer

Kyowa

EDX-5000A is an advanced all-in-one measuring instrument having sophisticated features and high-speed processing capabilities.
It is the high-end model of EDX Series.

Kyowa

EDX-5000A-80 – Memory Recorder/Analyzer

Summary

  • High-speed sampling at 200 kHz/32 channels
  • Up to 80 input channels (EDX-5000A-80)
  • Simultaneous recording of measuring data and video
  • Conditioner cards selectable for specific applications
  • Effective real-time processing capability

Technical Specifications

Model EDX-5000A-80-HE: Hard disk drive (HDD) , English
EDX-5000A-80-SE: Solid state drive (SSD) , English
Applicable Conditioner Cards CDV-40B (-F), CVM-41A, DPM-42B (-F), DPM-42B-I (-F), CTA-40A, CFV-40A, CCA-40A (-F), CDV-44AS, CDA-44AS, CDA-45AS, AD-40AS (-F)
Input Channels Max. 80 (CDV-40B x 10)
Analog Input See spec of respective conditioner cards.
Digital I/O I/O points: Max .8
I/O Settings: Sets every bit to digital input, digital output, or remote-control input with the same common.
*Remote-control input: Measuring start, stop, balance conducting, etc.

Input modes: Isolated TTL Level input
Input voltage: Max. 5 VDC
Isolation modes: Digital isolation
Output modes:Isolated open-collector output (With 10 k? built-in pull-up resistors)
Output voltage: 5 VDC
Output current: Max. 25 mA (per point)
Voice Input 1 channel (To be recorded together with measuring data.) An optional remote control unit RCU-42 is required.
Sampling Frequencies
Sampling Modes 1-2-5 series
1 Hz to 200 kHz for up to 32-channel data acquisition
1 Hz to 100 kHz for up to 64-channel data acquisition
1 Hz to 50 kHz for up to 80-channel data acquisition
1 Hz to 10 kHz for real-time synchronous data processing
2n series
2 to 131.072 Hz for up to 32-channel data acquisition
2 to 65.5536 Hz for up to 64-channel data acquisition
2 to 32.768 Hz for up to 80-channel data acquisition
2 to 8.192 Hz for real-time synchronous data processing
*The condition is using a 16-bit A/D converter.
*As for a 24-bit A/D converter, the channels above will be half of each channel.
Storage HDD model: 300 GB or more
SSD model: 30 GB or more
Display Channel status LED (OVER value of every channel are settable), REC, BUSY, BATTERY, POWER LED
12.1″ wide touchscreen
Operation Keys Keys (REC, STOP, BAL, and OPT) are operated by touchscreen, keys on EDX, external keyboard, or mouse
Output Control Connectors CONT.IN, CONT.OUT(For remote control unit, or synchronous operation)
External I/O Connectors External triggers: TRG IN, TRG OUT
External clock: CLK IN, CLK OUT
(Output at any frequency division ratio)
External Interfaces USB type keyboard, USB type mouse
VGA connector for monitor
USB I/F: 3 USB 2.0 in front, 2 USB 3.0 in rear
LAN I/F: 100/1000BASE-T
Power Supply 100 to 240 VAC and 10 to 30 DC, dual supply
Built-in batteries against momentary power failure
Current Consumption Approx. 2.0 A
(For 100 VAC, CDV-40B x 10)
Operating Temperature 0 to 40 ?C
Operating Humidity 20 to 80% RH (Non-condensing)
Storage Temperature -20 to 60 ?C
Vibration Resistant EDX-5000A-80-HE, EDX-5000A-80-SE
49.0 m/s2 (5 G), 5 to 55 Hz (When not operating)
29.4 m/s2 (3 G), 5 to 55 Hz (When operating)
EDX-5000A-80-HE:
9.8 m/s2 (1 G), 10 to 200 Hz (When operating)
EDX-5000A-80-SE:
19.6 m/s2 (2 G), 10 to 200 Hz (When operating)
Impact Resistant 196.1 m/s2 (20 G), 11 ms
Dimensions 410 W ? 159 H ? 300 D mm (Excluding protrusions)
Weight Approx. 12.5 kg (Mainframe only)
Optional Functions CAN data acquisition (Input channels: Max 512)
GPS data acquisition (Tracing data acquisition, time synchronous function)
Online Control Controlled by DCS-100A
EMC Directive EN61326-1 (Class A)
Low Voltage Directive EN61010-1
(Installation category II, Pollution degree 2)
RoHS Directive EN50581
Standard Accessories AC power cable P-18 (With 2-pin conversion plug
CM-39), DC power cable P-70, gound wire P-72, simplified instruction manual, CD-R (Instruction manual), EDX accessory bag, AC fuse, DC fuse, soldering plug for DIO, shell case for DIO plug
Optional Accessories Synchronous cable N-128, remote control unit RCU-42A , belt hook, dummy panel for EDX DX1PDUMMY, EDX-2000-DUMMY
Software Specifications
Measuring Condition Settings
Measuring Channel Conditions Measurement ON/OFF, measuring modes, range, HPF, LPF, digital HPF, digital LPF, balance ON/OFF, CAL, calibration coefficient, offset, offset zero ON/OFF, unit, channel name, measuring range, rated capacity, rated output, upper-limit check value, lower-limit check value, numeric display digits (Selects any items to display), inner sensitivity register ON/OFF, input cable, cable compensation value
Recordable Data Up to remaining disk space of built-in memory
Manual Measurement Recording from REC to STOP, or preset data starts from REC
Interval Measurement Automatic recording according to designated starting time and recording interval
Trigger Measurement ? Common trigger conditions
End trigger: Settable
Pre-trigger: Max. 2097152 points per channel
Post-trigger: Max. 2097152 points per channel
(When A/D is set to 24 bits)
Trigger data correlates with the number of channels.
? Analog trigger conditions
Trigger channels: Any 1 analog channel
Trigger level: Sets in physical quantity.
Trigger slope: Up, down
? Digital trigger conditions
Trigger bit: Any 1 bit
Trigger level: 0, 1
? External trigger conditions
Trigger slope: Up, down
? Complex trigger conditions
Trigger source: Selection of any 4 analog/
digital channels, an external trigger channel, or a manual trigger channel
AND/OR: Be used for analog
trigger, digital trigger and external trigger.
Trigger level: An physical quantity is set for
the analog channel, and 0 or 1 for the digital channel.
Trigger slope: Up, down
TEDS Reads sensor’s information and sets to channel condition automatically.
Measuring Operations
Real-time processing Simultaneous monitoring and recording of data
The sampling frequencies up to 10 kHz are available.
Video Data Acquisition with a Web Camera
Camera DirectX compatible Web camera
(Recognized by the OS as an imaging device)
Number of Cameras 1
Resolution Max. 640 x 480
Frame rate Max. 30 fps
Saving File Format AVI format
Resolution and frame rate depend on the camera.
The Web camera is optional.
Measuring Conditions during Recording Manual mode, manual mode (Data points preset)
Arithmetic Operation Calculation channels: Max. 64
Calculation conditions: ON/OFF, operators (Max. 200 characters), unit, numeric display digits, channel name (Max. 40 characters), calculation zero, and calculation zero value
Applicable Operators and Constants
+, -, ?, /, ^[power], P[I ?], ()
Functions:
SQR Square root
ABS Absolute value
SIN Sine
COS Cosine
TAN Tangent
ASIN Arc sine (Return value: Radian)
ACOS Arc cosine (Return value: Radian)
ATAN Arc tangent (Return value: Radian)
DSIN (Return value: Angle)
DCOS (Return value: Angle)
DTAN (Return value: Angle)
LOG Common logarithm
LN Natural logarithm
EXP Exponent
HMX Max. principal strain
HMN Min. principal strain
HSM Max. shearing strain
SMX Max. principal stress
SMN Min. principal stress
SSM Max. shearing stress
DEG Principal strain direction
FFT Analysis
Analysis Types Linear spectrum, power spectrum, cross spectrum, auto-correlation, and cross-correlation
Window Functions OFF, Hamming, Hanning, Fejer, Blackman, and Gaussian
Analyzed Data Points 256, 512, 1024, 2048, 4096, and 8192
Analysis Channels 4 channels/window
Saving File Format Kyowa standard file format (KS2)
KS2 file version: 01.06
Monitor
Y-time Graph X axis indicates the time, and Y axis the physical values of measurement for a maximum of 8 channels.
X-Y Graph X and Y axes indicate the measured data, max. 4 channels
Bar Graph Up to 80 channels are contained in a graph.
Displays max. and min. values are possible.
Circle Meter Any one channel is displayed in a circle meter.
Numeric Display Up to 80 channels are listed.
Displays max. and min. values of each channel are possible.
FFT Graph Up to 4 channels of analyzed results are displayed.
Web Camera Displays captured images.
Over-input Displays the over-input values, background, etc. in red.
Graph Scale Capable of displaying auto-scale value on the Y-time graph (Y axis), X-Y graph (X, Y axes), and bar graph (Y axis).
Cursors Available on Y-time graph, X-Y graph, physical values appear at the cursor positions
Windows Up to 12 different graph windows are available at the same time.
Saving Images Saves each graph as an image file.
Environmental Settings
Synchronous Operation Standalone, sync host, or sync guest is selected
Others Inner, external oscillators switching, operating beep, balance reference value, A/D bits switching, and optional switches selection
GPS/Multi-channel CAN Optional Functions
Can Data Recording Up to 512 channels of CAN data can be recorded
for each unit.
(CAN data is saved in E4A file format.)
*Use the ELA-55A for CAN condition settings.
Can Trigger Start/stop recording data by using analog triggers,
ditital triggers, and complex triggers.
*Use the ELA-55A for CAN condition settings.
Graph Display Display numerical and analog data in graphs simultaneously.
Point ZERO (Manual) Measurement Able to start manual measurement at zero second (at the moment when msec is zero) using the time data received from GPS satellites.
Interval (GPS Synchronization) Measurement Able to start interval measurement at zero second (at the moment when msec is zero) using the time data received from GPS satellites.
GPS Data Recording Able to monitor and record GPS data (latitude, longitude, speed, bearing, etc.).
GPS data is saved in NMEA file format.

 

Others

N/A