MR8740T – Memory HiCorder

Hioki

Max. 108 Analog Channels, Reduce Inspection Data Transfer Time to Zero

Hioki

MR8740T – Memory HiCorder (1GW memory, main unit only)

Overview

The MR8740T (MR8740-50) is rack-mountable data acquisition system that delivers high-speed, multi-channel measurements over maximum of 108 channels. Generate simulated signals and record at the same time using plug-and-play input units, making the waveform recorder ideal for evaluating multi-signal devices such as vehicle electronic control units (ECU).

Key Features

  • Ideal for multipoint inspection of high performance boards such as ECU.
  • 108ch analog to 96ch analog + 48ch logic input.
  • Reduce time required to save to external media to max.1/100 compared with conventional method.
  • 20 MS/s simultaneous sampling on all channels/
  • Safe measurement with all analog inputs isolated.
  • Supports 4K monitor to display multi-channel waveforms without overlapping.
  • Measure 4 channels with 1 unit (4 ch analog Unit U8975, 4 ch DVM Unit U8991).
  • Generate constant voltage, constant current, and simulated resistance (VIR Generator Unit U8794).
Category:
Number of input units Max. 27 slots
Number of channels [Using the U8975] Max. 108 ch analog, or 96 ch analog + 48 ch logic (when used in combination with U8975 + 8973)
[Using the 8966] Max. 54 ch analog, or 48 ch analog + 48 ch logic (when used in combination with 8966 + 8973)
*Logic unit 8973 is limited to slots 25 to 27, up to 3 units.
*Analog unit channels are isolated from each other and from chassis. Logic unit channels share a common GND with chassis.
Measurement ranges 100 mV to 400 V f.s., 12 ranges, resolution : 1/2000 of range (when using 8966)
4 V to 200 V f.s., 6 ranges, resolution : 1/32000 of range (when using U8975)
100 mV to 1000 V f.s., 5 ranges, resolution : 1/1000 000 of range (when using MR8990)
1 V, 10 V, 100 V f.s., 3 ranges, resolution : 1/1000 000 of range (when using U8991)
Max. allowable input 400 V DC (when using 8966; upper limit voltage that can be applied between input terminals without damage)
Max. rated voltage to earth 300 V AC/DC (input and instrument are isolated; between input channels and chassis; upper limit voltage that can be applied between input channels without damage)
Frequency characteristics DC to 5 MHz (-3 dB, when using 8966)
Max. sampling speed 20 MS/s, all ch simultaneous, external sampling: 10 MS/s
Measurement functions Memory (high-speed recording)
Memory capacity Total of 1 G Word installed, 16 MW/ch (when using 8966), 8 MW/ch (when using U8975 or MR8990), 4 MW/ch (when using U8991)
Internal storage SSD 480 GB
Removable storage USB memory stick ×8
Monitor output VGA, HDMI, Display Port, Recommended resolution 1920 × 1080 dot or more
External interfaces [LAN] 1000 BASE-T, 100 BASE-TX, 10 BASE-TX (2 port) (DHCP and DNS support, FTP server/cliant, HTTP server)
[USB] USB 3.0 Series A receptacle × 4, USB 2.0 ×4
Power supply 100 to 240 V AC, 50/60 Hz (400 VA max.)
Dimensions and mass 426 mm (16.77 in)W × 177 mm (6.97 in)H × 505 mm (19.88 in)D, 14.0 kg (493.8 oz) (main unit only)
Accessories Power cord ×1,Quick Start Manual (booklet) ×1, Instruction Manual (detailed edition) (CD-R) ×1, application disk (CD-R) ×1, blank panel (blank slot only), rack installation hardware