RM3543 – Resistance HiTester

Hioki

  • 10 m? to 1000 ? DC Resistance Meters with 0.01_? Resolution and Strong Noise Immunity for Integration into Automated Production Lines

Hioki

RM3543 – Resistance HiTester

Overview

Hioki DC resistance meters measure a broad range of resistance values at a high level of precision. The RM3543 is designed to be integrated into current sensing resistor taping machines, deliver high-accuracy measurement of super-low-resistance levels, and are advanced enough to measure 0.1 m? shunts with room to spare.

Key Features

  • Advanced enough to measure 0.1 m? shunts with room to spare at ?0.16% accuracy & 0.01_? resolution performance
  • Superb repeatable measurement accuracy
  • Advanced contact-check, comparator, and data export functions
  • Intuitive user interface and strong noise immunity are ideal for automated systems
Category:

Technical Specifications

Measurement method Four-terminal, constant-current DC
Resistance range 10 m? (Max. 12.00000 m?, 0.01 _? resolution) to 1000 ? range (Max. 1200.000 ?, 1 m? resolution), 7 steps
Display Monochrome graphic LCD 240 _ 64 dot, white LED backlight
Measurement accuracy [at 10 m? range, with SLOW mode, average 16 times settings] ?0.060 % rdg. ?0.001 % f.s.
Testing current [at 10 m? range] 1 A DC to [at 1000 ? range] 1 mA DC
Open-terminal voltage 20 V DC max. Note: Voltage when not measuring is 20 mV or less, with current mode set at PULSE and Contact Improver Setting set at OFF/PULSE (measured with a voltmeter having 10 M?)
Sampling rate FAST, MEDIUM, SLOW, 3 settings
Integration time [at 10 m? range, default value] FAST 2.0 ms, MED 5.0 ms, SLOW 1 PLC, Setting range: 0.1 ms to 100.0 ms, or 1 to 5 PLC at 50 Hz, 1 to 6 PLC at 60 Hz Note: PLC = one power line cycle (mains wave-form period)
Other functions Comparator (compare setting value with measurement value), Delay, OVC (offset voltage compensation), Average, Measurement fault detection, Probe short-circuit detection, Improve contact, Current mode setting (A pulse application function that applies current only during measurement), Auto-memory, Statistical calculations, Settings monitor (when using two instruments, a difference in settings causes warning notification), Retry, Trigger function. etc,.
Interfaces External I/O, RS-232C, Printer, GP-IB (Model RM3543-01)
External I/O Trigger, Hold input, Comparator output, Settings monitor terminal, Service power output +5V, +12V, etc.
Power supply 100 to 240 V AC, 50/60 Hz, 40 VA max.
Dimensions and mass 260 mm (10.24 in) W _ 88 mm (3.46 in) H _ 300 mm (11.81 in) D, 3.0 kg (105.8 oz)
Accessories Power cord _1, EXT. I/O male connector _1, Instruction manual _1, Operation guide _1

 

Others

N/A