,

SF4000 – GENNECT One

Hioki

Get Results from the Job Site in Real-Time & Capture Data on the PC while Testing Remotely

Hioki

SF4000 – GENNECT One (Application for Windows)

Overview

GENNECT ONE is a free PC software for Windows operating systems that lets you log data in real-time, import data and files, configure instrument settings, export native data as a CSV file and create reports with select Hioki measuring instruments.

Key Features

  • Connect measuring instruments to a PC via a LAN cable
  • Acquire measurement values from multiple measuring instruments at regular intervals and display them on a graph in real time. (*1)
  • Lay out measurement values on the image and able to check graphically (*1)
  • Connect measuring instruments to a PC via a LAN cable
  • Automatically transfer files saved on a LAN-connected measuring instrument to a PC (*3)
  • List MAX, MIN and AVG values (Display time of MAX & MIN data)
  • Real-time calculation of measurement values of arbitrary measurement items (calculation between channels)
  • Automatically output measurement data to daily/weekly/monthly report or CSV file

*1: Max. number of connections: 30 units, The measurement value (current location) displayed by the instrument is acquired at a fixed interval (minimum 1 second) by the PC timer.
*2: Max. number of connections: 30 units
*3: Max. number of connections: 15 units.

Logging

Functions • Generate monitor, graph, and list displays of measured values from LAN-connected instruments in real time. *
• Real-time calculation of measurement values of arbitrary measurement items (calculation between channels)
• Automatically output measurement data to daily/weekly/monthly report or CSV file

* Acquire measured values (current values) displayed on instruments at a set interval (as short as 1 sec.) using the computer’s timer.
* Max. 32 items when simultaneously displaying graphs

Logging intervals 1, 2, 5, 10, 30 sec.
1, 2, 5, 10, 30 min.
1 hour
Measured parameters • PW8001, PW6001, PW3390: Basic Measurement items, Harmonic measurement items (Instantaneous value per interval)
• PW3335, PW3336, PW3337: Basic Measurement items (Instantaneous value per interval)
• PQ3100, PQ3198, PW3365, PW3360: Voltage, Current, Power (Instantaneous value per interval, MAX, MIN, AVE values between intervals)
• LR8400, LR8401, LR8402, LR8410, LR8450, LR8450-01, MR6000: Various measurement items such as Temperature, Analog input, etc. (Instantaneous value per interval)
• Calculation between channels (up to 16 items)
Number of items able to monitor and log Max. 512 items + 16 items (calculation between channels)
Recording time Recording time: Continuous measurement,set time
File segmentation: 1 day, 1 hour
Logging stops when the storage capacity of the PC is below 512 MB
Max. number of connections 30 units

Dashboard

Functions • Monitor measured values in real time from LAN-connected instruments.*
• Display alarms in real time when a measured value exceeds a threshold.*
• Display measured values on a user-selected image.
• Real-time calculation of measurement values of arbitrary measurement items (calculation between channels)
• Automatically output measurement data to daily/weekly/monthly report or CSV file

* Acquire measured values (current values) displayed on instruments at a set interval (as short as 1 sec.) according to the computer’s timer.

Monitoring intervals 1, 2, 5, 10, 30 sec.
1, 2, 5, 10, 30 min.
1 hour
Measured parameters • PW8001, PW6001, PW3390: Basic Measurement items, Harmonic measurement items (Instantaneous value per interval)
• PW3335, PW3336, PW3337: Basic Measurement items (Instantaneous value per interval)
• PQ3100, PQ3198, PW3365, PW3360: Voltage, Current, Power (Instantaneous value per interval, MAX, MIN, AVE values between intervals)
• LR8400, LR8401, LR8402, LR8410, LR8450, LR8450-01, MR6000: Various measurement items such as Temperature, Analog input, etc. (Instantaneous value per interval)
• Calculation between channels (up to 16 items)
Number of stored parameters Max. 512 items + 16 items (calculation between channels)
Recording time Recording time: Continuous measurement
File segmentation: 1 day, 1 hour
Logging stops when the storage capacity of the PC is below 512 MB
Max. number of connections 30 units

Remote control

Functions Control LAN-connected instruments from a computer
Number of simultaneous operation 30 unit at a time

File transfer (Manual)

Interface LAN, USB (USB only for BT3554-50, BT3554, 3554)
Functions Acquire files stored in LAN-connected instruments from a PC
The BT3554-50 series can be acquired via USB.
Compatible instruments PQ3100, PQ3198, PW3360, PW3365, PW3390, PW6001, PW8001,
LR8400, LR8401, LR8402, LR8410, LR8416, LR8450, LR8450-01, MR6000, BT3554-50, BT3554, 3554
Number of simultaneous operation 1 unit at a time

File transfer (Automatic)

Functions Automatically send files saved by LAN-connected instruments to a computer.
Compatible instruments PQ3100, PQ3198, PW3360, PW3365, PW8001, LR8400, LR8401, LR8402, LR8410, LR8416, LR8450, LR8450-01, MR6000
Max. number of connections 15 units

Other functions

Files loading • Data file obtained by GENNECT Cross for iOS/Android
*Logging, General Measurement, image and battery formats only
*No direct Bluetooth® connection is possible, please use the smartphone app for Bluetooth® data collection
• Data file obtained by GENNECT Remote
• Measurement data folder (PQ3100, PQ3198, PW3360, PW3365)
• Measurement data file (LR8400 series, LR8410, LR8416, LR8450, MR6000, LR5000 series, PW3390, PW6001, PW8001)
Instrument clock
synchronization
Set the clocks of measuring instruments connected via LAN to the PC (manual, automatic)
CSV output Logging data, time-series measurement data, waveform files of instruments supporting time-series viewer, data files acquired by GENNECT Cross (standard measurement, battery)
Report creation PDF, Word and Excel formats

System requirements

Supported operating systems Windows 7 (32bit / 64bit)
Windows 8.1 (32bit / 64bit)
Windows 10 (32bit / 64bit)
Windows 11
Software environment Microsoft .NET Framework 4.6.2 or later
CPU Clock speed: 2 GHz or greater
RAM 4 GB or more
Display 1366 × 768 or better resolution
Hard drive 1 GB or more available space