WDS-190AS1E Compact Digital Indicator

Channels 1
Compatible Transducer Strain gage transducer
Compatible Bridge Resistance 60 to 1000 Ω
Bridge Excitation 2 VDC (Constant)
Measuring Range ±5 mV/V (±10000 μm/m), including zero adjustment range
Digital Zero Executes digital zero within the measuring range
Sampling Approx. 50 times/sec
Calibration LOAD ADJ (Actual load calibration), ENROLMENT ADJ (Sensitivity registering calibration), TEDS functions: ENROL BY TEDS (TEDS data only)
ENROL BY FILES (TEDS data + calibration files)
Indication LCD: 128×64 dots, backlight (on / off)
Range: -99999 to 99999
Decimal point position: Sets to anywhere possible, MEASURE mode only Unit: Select from 28 types and custom units
Indication Accuracy Within ±(0.05% of reading +5×10-6) m/m
Modes STRAIN mode: Switchable between “μm/m” and “mV/V” MEASURE mode: Proper engineering units
Smoothing Moving average: 1/2/4/8/16/32/64/128
Minimum scale: 1, 2, 5, 10, 20, 50, 100 steps
Zero-near-zero: 0 to 9
Peak Hold Digitally holds a maximum value during measurements
Low Power Power OFF: 1 to 99 min or 00 (OFF)
Backlight OFF: 1 to 99 sec or 00 (OFF)
Battery Remaining Capacity Battery mark lights up 1/1, 1/2, 1/4, and battery mark blinks. When the battery mark blinks: Prohibit settings/calibrations/recordings
Operating Temperature -10 to 40℃
Operating Humidity 20 to 85% (Non-condensing)
Storage Temperature -10 to 60℃
Power Supply AA size alkali battery × 2
Operating Time Approx. 72 hours continuously (With alkali batteries, 350 Ω transducer, backlight OFF, and temperature 25℃)
Dimensions 66.5 W × 92 H × 28 D mm (Excluding protrusions)
Weight Approx. 110 g (Excluding batteries)
Optional Accessories Input cable U-16
Soft case WDS-500-CASE (With shoulder strap)
Bridge box DB-120C-2/3

WDS-191AS1E Compact Digital Indicator with recording functions

Channels 1
Compatible Transducer Strain gage transducer
Compatible Bridge Resistance 60 to 1000 Ω
Bridge Excitation 2 VDC (Constant)
Measuring Range ±5 mV/V (±10000 μm/m), including zero adjustment range
Digital Zero Executes digital zero within the measuring range
Sampling Approx. 50 times/sec
Calibration LOAD ADJ (Actual load calibration), ENROLMENT ADJ (Sensitivity registering calibration), TEDS functions: ENROL BY TEDS (TEDS data only)
ENROL BY FILES (TEDS data + calibration files)
Indication LCD: 128×64 dots, backlight (on / off)
Range: -99999 to 99999
Decimal point position: Sets to anywhere possible, MEASURE mode only Unit: Select from 28 types and custom units
Indication Accuracy Within ±(0.05% of reading +5×10-6) m/m
Modes STRAIN mode: Switchable between “μm/m” and “mV/V” MEASURE mode: Proper engineering units
Smoothing Moving average: 1/2/4/8/16/32/64/128
Minimum scale: 1, 2, 5, 10, 20, 50, 100 steps
Zero-near-zero: 0 to 9
Peak Hold Digitally holds a maximum value during measurements
Comparator Upper limit ×1
Clock Year/month/day/hour/minute/second based on Christian era (Clock settings are year/month/day/hour/minute only)
Recording Record each time REC key is pressed (saved as CSV text file, 2 GB memory)
Data: Date, time, part name, count value, measured value, unit, limit value, comparator ON/OFF (arbitrary setting of part name and count value possible)
Interfaces USB2.0 (Micro USB)
Low Power Power OFF: 1 to 99 min or 00 (OFF)
Backlight OFF: 1 to 99 sec or 00 (OFF)
Battery Remaining Capacity Battery mark lights up 1/1, 1/2, 1/4, and battery mark blinks. When the battery mark blinks: Prohibit settings/calibrations/recordings
Operating Temperature -10 to 40℃
Operating Humidity 20 to 85% (Non-condensing)
Storage Temperature -10 to 60℃
Power Supply AA size alkali battery × 2
Operating Time Approx. 72 hours continuously (With alkali batteries, 350 Ω transducer, backlight OFF, and temperature 25℃)
Dimensions 66.5 W × 92 H × 28 D mm (Excluding protrusions)
Weight Approx. 110 g (Excluding batteries)
Optional Accessories Input cable U-16
Soft case WDS-500-CASE (With shoulder strap)
Bridge box DB-120C-2/3