| Calibration |
Type |
Sensitivity Reg. Cal, Actual Load Cal, Numeric Value Reg. Cal, TEDS manual calibration, TEDS auto calibration |
|
|
Target CH: CH1, CH2 |
|
Sum CH |
1 |
|
|
Arithmetic expression: |
|
|
(CH1 + CH2) × Coefficient of Multiplication |
|
Diff. CH |
1 |
|
|
Arithmetic expression: |
|
|
(CH1 – CH2) × Coefficient of Multiplication |
|
|
or |
|
|
(CH2 – CH1) × Coefficient of Multiplication |
|
|
selectable |
|
Coefficient of Multiplication |
× 0.01 to × 10.00 |
|
|
Target CH: Sum CH, Diff. CH (Individually configurable) |
|
|
Manual setting: |
|
|
Set any value as Coefficient of Multiplication |
|
|
Automatic Caln: |
|
|
To calculate the multiplication coefficient from Sum (difference) of current CH1 and CH2 measurements and Target Value. |
|
Decimal Point Position |
Arbitrary setting is available (common with All channels) |
|
Unit |
Can be set for each channel |
| Filter |
Low-pass Filter |
10, 30, 100, 300 Hz, None (1 kHz or over) |
|
Moving Average |
None, 2, 5, 10, 20, 50, 100, 200, 500, 1000, 2000, 4000 times |
|
Minimum Scale |
1, 2, 5, 10, 20, 50, 100 |
|
Target CH |
Common with All channels |
| Digital Zero |
Digital Zero Memory |
When executed by main unit operation: retained |
|
|
By Control input, by command: Hold/not hold selectable |
|
Noise Monitoring Width |
0 to 100% (Percentage value for 6.4 mV/V) |
|
Target CH |
CH1 & CH2 batch execution |
|
|
(Executable for each channel only when executed by operation of the main unit or by command) |
| Add Function |
Addition Value Enable |
Enable/Disable |
|
Addition Value |
0 to ±99999 count |
|
|
Manual setting: Sets any value as an Addition Value and adds it. |
|
|
Tare Subtraction: Set the current measured value multiplied by -1 as the additive value and add. |
|
Target CH |
Manual setting: |
|
|
CH1, CH2, Sum CH, Diff. CH (Individually configurable) |
|
|
Tare Subtraction: |
|
|
CH1, CH2 (Individual execution/ Batch execution) |
|
Control of Add Function |
Manual, Control Input, Command |
| One-side Operation |
|
Disable, CH1 × 2, CH2 × 2 |
| Comparison |
The Number of Points |
8 |
|
Each Comparator Enable/Disable |
Selectable |
|
Target CH |
CH1, CH2, Sum CH, Diff. CH |
|
|
Multiple comparators can be set on the same channel |
|
Comparator Name |
Alphabet, Numerics, Symbol (max. 2 characters) |
|
Comparison Value |
±99999 count, Select over or under |
|
Display Color |
Select 1 color (total 8 colors) |
|
Comparator Output Logic |
Positive/ Negative |
|
Comparison Mode |
Always compare |
|
Hysteresis Width |
0 to 9999 count |
|
Comparison Speed |
4000 times/sec (When Always compare) |
| Judgment |
The Number of Points |
1 |
|
Target Comparators |
Up to 4 of 8 Comparators can be selected |
|
Judgment Conditions |
AND, OR |
|
Judgment Output Logic |
Positive/ Negative |
|
Judgment Mode |
Always Judgment |
| DA Output |
The Number of Points |
8 |
|
Each DA Output Enable/Disable |
Selectable |
|
Target CH |
CH1, CH2, Sum CH, Diff. CH |
|
DA Output Assignment |
Measured value |
|
Scaling |
Zero Display Value |
|
|
(Displayed value when the voltage 0 V is outputted). |
|
|
Full Scale Display Value |
|
|
(Displayed value when the voltage 10 V is outputted) |
|
Auto Scaling |
Enable/Disable |
|
|
(Valid only for CH1 and CH2) |
|
|
(If enabled, set the value of Rated Display to Full Scale |
|
|
Display Value when calibrating) |
|
Reflects Minimum Scale |
Enable/Disable |
| Display Settings |
Number of Channels Displayed |
1, 2, 4 |
|
Indication |
Numerics |
|
Comparator Name |
Alphabet, Numerics, Symbol (max. 8 characters) |
|
Display Value Averaging |
Enable/Disable |
| Setting Pattern |
The Number of Patterns |
4 |
|
Setting Range |
Each Calibration value, Addition value, Comparison function settings, Judgment function settings, Digital Zero Values, DA Output function settings |
|
Control of Setting Pattern |
Manual, Control Input, Command |
| Communication Settings |
Interface |
USB, RS-485 |
|
Transmission Speed Setting |
9600, 19200, 38400 bps |
|
Delimiter Setting |
Received Delimiter: CR, LF, CRLF |
|
|
Sending Delimiter: CR, LF, CRLF |
|
Device ID |
01 to 99 (RS-485 only) |
|
Transmission Mode |
Tx and Rx |
| Check function |
Original Value Check |
Display range: -3.2000 to 3.2000 mV/V (5 digits) |
|
|
Display accuracy: within ±0.1% FS |
|
Level Test |
Arbitrary values can be displayed |
|
|
Level Test Value: |
|
|
±99999 count |
|
|
Add Level Test Value to Display Value: |
|
|
Enable/Disable |
|
|
Control of Level Test: |
|
|
Manual/Control Input/Command |
|
Power-on Check |
Enable/Disable |
|
|
(Check Contents: Bridge Excitation, Built-in Memory) |
|
Other Checks |
Bridge Excitation, Control I/O, Communication, SD card, Built-in Memory, Touch Panel, Display Color, LED |
| Data |
Setting Save |
Save all settings to SD card |
|
Setting Read |
Read all settings from SD card |
| Configuration Settings |
|
Language (Japanese/English), Backlight off Time, Date & Time, |
|
|
Version, Update, SD Card Format, Set Initialize |